SCS 6E Automatic PC Compatible Solvent-Fat Extraction System with Economic Version
SCS 6E Automatic PC Compatible Solvent-Fat Extraction System with Economic Version

SCS 6E Automatic PC Compatible Solvent-Fat Extraction System with Economic Version

MOQ : 1 Unit

SCS 6E Automatic PC Compatible Solvent-Fat Extraction System with Economic Version Specification

  • Operating Voltage
  • 220V AC
  • Gas Pressure
  • 0.2~0.3 MPa
  • Equipment Type
  • Automatic Solvent-Fat Extraction System
  • Features
  • Economic Version, solvent recovery system, safety protection, rapid extraction process
  • Automation Grade
  • Automatic
  • Measuring Range
  • 0.01g~99.99g
  • Max Height
  • 400 mm
  • Display Type
  • Digital LCD display
  • Accuracy
  • ±0.01g
  • Response Time
  • ≤3 seconds
  • Power Supply
  • 220V AC ±10%, 50 Hz
  • Mounting Type
  • Bench-top
  • Temperature
  • 5°C~40°C
  • Resolution
  • 0.01g
  • Test Range
  • 0.01g ~ 99.99g
  • Humidity
  • ≤80% RH
  • Specimen Size
  • 10-50 g
  • Interface Type
  • USB & PC connectivity
  • Application
  • Determination of fat content in food, feed, and other organic samples
  • Frequency
  • 50 Hz
  • Number of Specimens
  • Up to 6
  • Port Size
  • Standard 1/4 inch
  • Hardness
  • Industrial grade materials
  • Usage
  • Laboratory analysis for fat extraction
  • Capacity
  • 6 extraction positions
  • Machine Weight
  • 55 kg
  • Test Speed
  • Adjustable via software interface
  • Test Width
  • Up to 250 mm
  • Test Stroke
  • 150 mm
  • Control Mode
  • Automatic & PC compatible
  • Dimension
  • 600x350x400 mm
  • Exhaust System
  • Integrated active exhaust for solvent vapors
  • Ambient Conditions
  • Non-condensing, dust-free environment
  • Noise Level
  • ≤45 dB
  • Extraction Method
  • Soxhlet and Randall support
  • Software
  • User-friendly PC software for extraction process monitoring and reporting
  • Cleaning
  • Automatic cleaning cycle with programmable duration
  • Material of Construction
  • High-quality stainless steel and corrosion-resistant polymer
  • Compliance
  • Meets ISO 11085:2015 & AOAC standards
  • Safety Features
  • Over-temperature protection, solvent leak protection and automatic shutdown
  • Solvent Type
  • Compatible with petroleum ether, hexane, and other extraction solvents
  • Data Storage
  • Internal memory for up to 1000 test results
  • Waste Handling
  • Automated waste separation and disposal system
  • Extraction Time
  • 15~45 minutes (adjustable)
 

SCS 6E Automatic PC Compatible Solvent-Fat Extraction System with Economic Version Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 4 Week
 

About SCS 6E Automatic PC Compatible Solvent-Fat Extraction System with Economic Version

  • Automatic Programmable Six Place Auto sequencing PC Compatible Solvent Extraction System with Economic Version
  • Application: Rapid, economic and safe estimation of soluble material for selective extraction of solid and semi solid products by solvents with Randall technique in samples like food, feed, egg, meat, meat products, milk, dairy products, confectionary products, soil, polymers, textiles, paper, pulp, aromatic and medicinal plants, flower essence, cereals, pulses, oil seeds, fruits, lipids and other dietary samples
  • Casted Aluminium Alloy Heaters for uniform heating, Independent loading of sample with individual mechanical controls,
  • Integrated auto sequencing time/temperature domain of 2 programs with 8 sequencing steps in each programme,
  • Temperature Controller is isolated separately in a control tower to protect electronics from solvent area & heat zone for safe operation, with separate access door for main unit & electronics control tower unit.
  • RS 232 interface for PC/ Laptop Connectivity,
  • Auto Phase changeover of 5 stage extraction includes boiling, Condensation, rinsing, solvent recovery and Pre-drying steps, Digital Display, Auto switch off at end of extraction procedure, Versatile to accommodate 2 sizes of Thimbles.
Payment Terms : 50% while placing Order and 50% before despatch of Equipment.


User-Friendly Automation and High Throughput

The SCS 6E offers fully automatic operation and intuitive PC compatibility, enabling seamless management of extraction processes. With six extraction positions and adjustable test speed, laboratories can efficiently process multiple samples, drastically improving workflow and productivity. Digital LCD display and software-based adjustments allow precision across varying specimen sizes and extraction parameters.


Robust Safety and Environmental Features

Built-in over-temperature protection, solvent leak detection, and automatic shutdown safeguard both users and samples during operation. An integrated active exhaust system minimizes solvent vapor exposure, and automated waste separation with solvent recovery enhances both lab safety and environmental compliance, making it suitable for demanding laboratory environments.


Precision Results and Broad Applicability

Supporting a measuring and test range from 0.01g to 99.99g, the SCS 6E achieves results with 0.01g accuracy and rapid response. This system accommodates various extraction solvents, such as petroleum ether and hexane, making it versatile for applications in food, feed, and organic matter analysis. Internal memory stores up to 1000 test results for traceability and easy reporting.

FAQ's of SCS 6E Automatic PC Compatible Solvent-Fat Extraction System with Economic Version:


Q: How does the SCS 6E Solvent-Fat Extraction System operate?

A: The SCS 6E uses fully automatic modes compatible with PC software for initiating, monitoring, and documenting solvent-fat extractions using Soxhlet and Randall methods. Users load samples (10-50g), select desired parameters, and the machine processes up to six samples simultaneously.

Q: What extraction solvents can be used with the system?

A: The system supports petroleum ether, hexane, and other commonly used extraction solvents, providing flexibility for labs to comply with specific analytical methods.

Q: When should automatic cleaning cycles be initiated?

A: Automatic cleaning cycles can be programmed and are recommended after each extraction run or when a change in solvent type occurs. This helps maintain instrument performance and prevents cross-contamination.

Q: Where is the SCS 6E best utilized?

A: Ideal for laboratory settings involved in food, feed, and organic sample analysis, the compact bench-top design fits easily into most lab environments and supports high-throughput testing demands.

Q: What is the extraction process and time frame?

A: Samples undergo solvent extraction via Soxhlet or Randall method, with adjustable parameters for optimal results. The extraction process takes between 15 to 45 minutes, depending on sample quantity and method chosen.

Q: How does the system ensure operator safety?

A: The SCS 6E is equipped with over-temperature protection, solvent leak detectors, automatic shutdown functions, and an active exhaust for safe handling of solvent vapors, ensuring secure operation in compliance with laboratory standards.

Q: What are the benefits of using this automatic extraction system?

A: Users benefit from faster extraction cycles, accurate and repeatable results, robust safety mechanisms, reduced manual handling of solvents, effortless maintenance with automated cleaning, detailed PC-based reporting, and efficient data storage for up to 1000 results.

Tell us about your requirement
product

Price:  

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fat Analyser Category

SCS 4R TS Automatic PC Compatible Solvent-Fat Extraction System with Touch Screen Display Version

SCS 4R TS Automatic PC Compatible Solvent-Fat Extraction System with Touch Screen Display Version

Minimum Order Quantity : 1 Unit

Application : Fat Content Determination in Food Products, Feed Samples

Mounting Type : Bench Top

Response Time : Instant Data Display

Power Supply : 230 V AC, 50 Hz

Temperature : 0°C to 40°C

SCS 4E Automatic PC Compatible Solvent-Fat Extraction System with Economic Version

SCS 4E Automatic PC Compatible Solvent-Fat Extraction System with Economic Version

Minimum Order Quantity : 1 Unit

Application : Measuring and extracting fat content from various samples (food, feed, etc.)

Mounting Type : Benchtop/Laboratory

Response Time : Rapid (full extraction within 4560 minutes)

Power Supply : AC 220V, 50Hz

Temperature : 5°C 40°C



Back to top