SCS 4R TS Automatic PC Compatible Solvent-Fat Extraction System with Touch Screen Display Version
SCS 4R TS Automatic PC Compatible Solvent-Fat Extraction System with Touch Screen Display Version

SCS 4R TS Automatic PC Compatible Solvent-Fat Extraction System with Touch Screen Display Version

MOQ : 1 Unit

SCS 4R TS Automatic PC Compatible Solvent-Fat Extraction System with Touch Screen Display Version Specification

  • Features
  • Automatic Solvent Addition/Removal, Data Logging, PC Compatible, Touch Screen Control
  • Number of Specimens
  • 4
  • Power Supply
  • 230 V AC, 50 Hz
  • Port Size
  • Standard 18 mm
  • Accuracy
  • ±0.1%
  • Specimen Size
  • up to 50 g
  • Application
  • Fat Content Determination in Food Products, Feed Samples
  • Test Range
  • 0.1% to 99.9% Fat Content
  • Mounting Type
  • Bench Top
  • Max Height
  • 56 cm
  • Display Type
  • Touch Screen
  • Temperature
  • 0°C to 40°C
  • Frequency
  • 50 Hz
  • Humidity
  • 10% to 80% RH
  • Automation Grade
  • Automatic
  • Interface Type
  • USB, RS232
  • Resolution
  • 0.01%
  • Equipment Type
  • Solvent-Fat Extraction System
  • Measuring Range
  • 0.1% to 99.9%
  • Operating Voltage
  • 230 V AC
  • Response Time
  • Instant Data Display
  • Gas Pressure
  • 0.2-0.6 MPa
  • Usage
  • Laboratory, Research Institutes, Industrial Quality Assurance
  • Capacity
  • 500 ml flask per unit
  • Machine Weight
  • 36 kg
  • Test Speed
  • Programmable
  • Test Width
  • Sample dependent
  • Test Stroke
  • 0-180 mm
  • Control Mode
  • Automatic & PC Compatible
  • Safety Features
  • Overload protection, Solvent leak detection, Automatic shut-off
  • Fume Exhaust
  • Integrated fan with hose adapter
  • Material of Construction
  • Stainless Steel
  • Sample Trays
  • PTFE coated holders for chemical resistance
  • Data Export
  • USB/PC connectivity for direct export
  • Extraction Method
  • Automatic solvent extraction (Soxhlet method)
  • Compliance
  • ISO 8294, AOAC Official Methods
  • Display Interface
  • 7-inch Color Touch Screen
  • Processing Capacity
  • Simultaneous testing up to 4 samples
  • Software Support
  • Windows-compatible control and report software
  • Solvent Compatibility
  • Petroleum ether, Hexane, Diethyl ether, Ethanol, other approved solvents
  • Cycle Time
  • 30-60 min per operation
 

SCS 4R TS Automatic PC Compatible Solvent-Fat Extraction System with Touch Screen Display Version Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 4 Week
 

About SCS 4R TS Automatic PC Compatible Solvent-Fat Extraction System with Touch Screen Display Version

  • Fully Automatic Programmable Four Place Auto sequencing PC Compatible Solvent Extraction System with Touch Screen Display Version
  • Application: Rapid, economic and safe estimation of soluble material for selective extraction of solid and semi solid products by solvents with Randall technique in samples like food, feed, egg, meat, meat products, milk, dairy products, confectionary products, soil, polymers, textiles, paper, pulp, aromatic and medicinal plants, flower essence, cereals, pulses, oil seeds, fruits, lipids and other dietary samples
  • TFT Graphic Touch Screen Display with unique wireless mouse to operate at a distance of 1-2 metres without connecting to PC.
  • 2 Ports in the motherboard one for PC connectivity another for direct connection to Remote Mouse / Memory stick for data storage
  • Integrated auto sequencing time/temperature domain of > 50 programs and >10 sequencing steps.
  • Tab key in Touch Screen for USB Copy & Graph representation with Time temp curve & bar chart graph
  • Temperature Controller is isolated separately in a control tower to protect electronics from solvent area & heat zone for safe operation, with separate access door for main unit & electronics control tower unit.
  • Inbuilt Software enables multi user login feature in touch screen display with password protection for different user level for Administrator, supervisor and End user through Admin login, User login & Service login.
  • Unique driver software to link Touch screen controller to Data processing system through wireless remote control module.
  • Speed of extraction: 40 to 60 minutes depending on application
  • Auto Phase change of extraction includes boiling, Condensation, rinsing, solvent recovery & pre-drying
  • Inbuilt software performs Live graphical representation of time /temperature gradient on touch screen display
  • Inbuilt Air pump, SS Manifold, Automatic collection of recovered Solvent, Versatile sizes of thimble,
  • Remote control module for wireless data monitoring, control and transfer to PC at a distance of 5-10 feet with remote transmitter and remote receiver.
  • Inbuilt Data logger with real time date & clock with memory stick for data storage with display of live data logging process with graph in Touch screen display.
Payment Terms : 50% while placing Order and 50% before despatch of Equipment.


Effortless Simultaneous Fat Extraction

The SCS 4R TS enables simultaneous testing of up to four specimens, optimizing laboratory efficiency and throughput. The system offers fast, programmable fat extraction by automatically regulating solvent addition and removal through the modern touch screen interface. Its robust processing capacity and repeatability make it a preferred solution for diverse testing needs in food science, research, and industry.


Comprehensive Solvent Compatibility and Safety

Engineered to support a broad range of solvents such as petroleum ether, hexane, diethyl ether, and ethanol, the system ensures flexibility across multiple testing protocols. Enhanced with safety features including overload protection, solvent leak detection, and automatic shut-off, it safeguards users and preserves sample integrity throughout the extraction process.


Advanced Connectivity and Data Management

With USB and RS232 ports and Windows-compatible software, the SCS 4R TS allows for seamless data export and real-time monitoring. The intuitive 7-inch touch screen interface provides instant data display and facilitates easy control. Its built-in data logging function streamlines the management and retrieval of laboratory results, supporting traceability and compliance requirements.

FAQ's of SCS 4R TS Automatic PC Compatible Solvent-Fat Extraction System with Touch Screen Display Version:


Q: How does the SCS 4R TS perform fat extraction in food and feed samples?

A: The SCS 4R TS uses an automatic Soxhlet solvent extraction method where solvents such as petroleum ether or hexane extract fat from samples loaded into PTFE-coated holders. The process is fully automated and allows simultaneous extraction from up to four specimens, ensuring precise and reproducible results.

Q: What safety features are incorporated in the SCS 4R TS extraction system?

A: Key safety features include overload protection, solvent leak detection, and automatic shut-off functions. These elements, combined with robust stainless steel construction and an integrated fume exhaust fan with a hose adapter, provide a secure and controlled environment during operation.

Q: When should this system be chosen over manual fat extraction methods?

A: The SCS 4R TS is ideal for laboratories, research institutes, or industrial quality assurance settings requiring high-throughput, accuracy, and compliance with international standards. Its automatic functions and programmable settings greatly reduce manual intervention, saving time and lowering operator error compared to manual methods.

Q: Where can data from the extraction process be exported or stored?

A: Extraction data can be directly exported to a computer using USB or RS232 connectivity. The included Windows-compatible software supports detailed data logging and report generation, enabling seamless integration with existing laboratory information management systems (LIMS).

Q: What is the typical processing time for a complete fat extraction cycle?

A: Each operation cycle ranges from 30 to 60 minutes, depending on solvent type, sample size (up to 50 g each), and extraction requirements. The system's programmable test speed allows for process optimization based on specific sample characteristics.

Q: How is the SCS 4R TS installed and maintained for optimal operation?

A: Designed for bench-top mounting with a max height of 56 cm, installation requires a 230 V AC power supply and connection to a suitable exhaust system. Routine maintenance involves regular cleaning, ensuring proper solvent replenishment, and checking for any safety alerts displayed on the unit's touch screen.

Q: What advantages does the touch screen interface offer during operation?

A: The 7-inch color touch screen simplifies process control, enabling instant data display and intuitive navigation through settings. Users can easily program tests, monitor extraction progress, and receive safety or maintenance notifications, enhancing productivity and reducing the learning curve.

Tell us about your requirement
product

Price:  

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fat Analyser Category

SCS 6E Automatic PC Compatible Solvent-Fat Extraction System with Economic Version

SCS 6E Automatic PC Compatible Solvent-Fat Extraction System with Economic Version

Minimum Order Quantity : 1 Unit

Application : Determination of fat content in food, feed, and other organic samples

Port Size : Standard 1/4 inch

Accuracy : ±0.01g

Specimen Size : 1050 g

Power Supply : 220V AC ±10%, 50 Hz

SCS 4E Automatic PC Compatible Solvent-Fat Extraction System with Economic Version

SCS 4E Automatic PC Compatible Solvent-Fat Extraction System with Economic Version

Minimum Order Quantity : 1 Unit

Application : Measuring and extracting fat content from various samples (food, feed, etc.)

Port Size : Standard 6 mm

Accuracy : ≤0.5% relative error

Specimen Size : ≤ 50 ml per extraction cup

Power Supply : AC 220V, 50Hz



Back to top