About CLASSIC DX Automatic Distillation System
- Fully Auto-run Completely Programmable Microprocessor based Distillation System with in-built software,
- 100 predefinable User Storage Programmes.
- Application: Total Nitrogen, Organic Nitrogen, Protein Determination, Available Nitrogen, Nitrate Nitrogen, Nitrite Nitrogen, Ammonical Nitrogen, Devarda Nitrogen Determination
- Automatic Boric Acid Addition, Dilution, KMNO4 Addition for Available Nitrogen, Alkali Addition, Steam Processing, Automatic Residue Removal with delay time features, Process over indication with alarm, Micro brilliant distillate control, Titration Connectivity feature for future upgradation with complete automatic safety features, Two-line Alpha numeric Digital LCD Display,
- The suction module of waste residue is door mounted for easy serviceability.
- Enables Automatic monitoring and measuring of high temperature in distillate with sensor for auto warning signal and safety alarm to alert user to control distillate temperature. Temperature displayed digitally.
- Auto reagent Level Sensor with Alarm, Stainless steel non corrosive steam Generator, Automatic water level monitoring & Peristatic pump for reagents addition
- Reagent tanks (2 litres) wall mounted for easy handling and users visibility.
- The control panel unit along with inbuilt temperature controller, timer, mother board and SMPS is isolated in separate control tower (not rack mounted internally) and housing to protect electronics from wet chemistry & acid/ alkali process area for longevity and safety of all electronic components, with separate access door for main unit & electronics control tower unit.
- Equipment incorporates transparent view window to watch the distillation process & splash head.
- Non Corrosive robust metallic condenser
Payment Terms : 50% while placing Order and 50% before despatch of Equipment.
Cutting-Edge Performance in Water DistillationEngineered for exceptional reliability, the CLASSIC DX delivers high purity distillate at a steady 2 L/hr rate. Its automatic flow control and microprocessor-driven temperature accuracy streamline your laboratory workflow, making it an optimal solution for precise distillation requirements.
Premium Construction and Safety AssuredCrafted from SS 304 stainless steel and high-purity borosilicate glass, the device ensures long-lasting use and resistance to corrosive substances. Built-in safety interlocks, automatic overheat protection, and a reliable power cut-off enhance operational safety for every use.
Effortless Operation and Low MaintenanceThe system features a soft-touch digital control panel and clear LED display for straightforward operation. Its integrated efficient water cooling and easy-access manual drain design simplify maintenance and cleaning while reducing overall water consumption.
FAQ's of CLASSIC DX Automatic Distillation System:
Q: How does the CLASSIC DX Automatic Distillation System ensure high purity in the distillate output?
A: The CLASSIC DX uses high-purity borosilicate glassware and an advanced rustproof immersion heater. These components, combined with automatic operation and precise digital control, minimize contamination and maintain low conductivity, resulting in consistently high-purity distillate.
Q: What is the process for operating and maintaining the CLASSIC DX distillation apparatus?
A: Operation is fully automatic with a digital microprocessor control panel. You simply fill, select settings on the soft-touch digital switch, and let the system run. Maintenance is minimal due to easy-clean surfaces, an accessible manual drain, and efficient cooling that reduces deposit buildup.
Q: When is this system most beneficial for laboratory applications?
A: The CLASSIC DX is ideal for routine and high-demand laboratory tests requiring distilled water or solvents. Its reliable 2 L/hr output, high temperature resistance, and automated controls make it especially suitable for quality testing and precise analytical tasks.
Q: Where can the CLASSIC DX be installed in the laboratory?
A: Designed as a bench-top system, the device fits conveniently on laboratory counters with standard power connections. Its compact footprint (540x420x880 mm) and single-phase power supply allow flexible placement without specialized installation requirements.
Q: What safety features are incorporated into the CLASSIC DX Automatic Distillation System?
A: Safety is ensured by a built-in overheat protection with automatic power cut-off, water level monitoring, tough glassware, and robust stainless-steel construction. These safeguards prevent overheating and accidental damage, ensuring safe and stable operation.
Q: How does the integrated cooling system benefit users in terms of water and energy consumption?
A: The efficient integrated water cooling system consumes minimal water while maintaining optimal cooling performance. This not only conserves resources but also lowers operational costs and supports sustainable laboratory practices.